Skip to content
БОТГЕРЦ
Language RU EN 中文
Medium 17.11.2026

Refrigerated trucks: temperature control via 1-Wire

How to monitor cargo temperature with 1-Wire sensors: connection, configuration, thresholds and what to check in monitoring.

For equipment: ASN BOTHERTZ-24

The task

For a refrigerated truck, not only coordinates matter but also cargo temperature. The carrier must see what happened in the body along the whole route, not only at the moment of unloading.

BOTHERTZ-24 ASN receives temperature sensor data over the 1-Wire interface and transmits it in telemetry.

What you will need

  • BOTHERTZ-24 ASN with transmission configured.
  • 1-Wire temperature sensors.
  • Access to the monitoring system to configure reports and events.

How to connect

  1. Choose the control points. Usually one sensor goes by the evaporator and the second deep in the cargo or by the door.
  2. Mount the sensors. Fix them so that they do not touch the walls and are not exposed directly to the cold air flow.
  3. Connect 1-Wire. Connect the sensors to the unit and check that they are visible in the configurator.
  4. Configure transmission. Check that temperature arrives in monitoring and is stored in the history.
  5. Set thresholds. Configure events: going outside the permitted range, a sharp change, absence of data.

What to look at in reports

  • Temperature from each sensor over the trip.
  • The time the threshold was exceeded and the duration of the deviation.
  • The difference between sensors — a sign of problems with airflow or the door.
  • Gaps in data — a sign of a communication or power issue.

Common mistakes

  • The sensor is fixed to the wall and reads the temperature of the metal rather than of the cargo.
  • Thresholds are set in the monitoring system, but events are not configured.
  • The sensors are connected but not checked in the configurator.
  • There is no history: data is coming in but is not stored in reports.

What to check before a trip

  • All sensors are visible in the configurator.
  • Temperature is being transmitted to monitoring.
  • Thresholds and notifications work.
  • The history for the previous trip is available.

If a sensor is not visible, check the 1-Wire connection and the device address. Temperature sensors use separate addressing that is not related to the FLS channels.

Sources

  • bothertz.ru/equipment — "ASN" section, accessed 17.11.2026
  • docs.duotec.ru/99/monitoring.html — "Data transmission", accessed 17.11.2026

Reviewed: 17.11.2026

Legal information

This material is for information only and is not a legal opinion. Check the current edition of the act and whether the requirement applies to your vehicle category and import/release basis. For legal advice, consult a lawyer.

Read next

Other guides

All guides →

Next step

Let us scope your project