BG24-ASN-M2 receives data from fuel level sensors over two channels:
| Channel | Quantity | When to use |
|---|---|---|
| RS-485 | up to 8 sensors | Special-purpose machinery, long-haul tractors, several tanks, requirements for data continuity |
| Bluetooth LE | up to 4 sensors | Minimal installation, small fleets, when you do not want to run cable |
Temperature sensors are connected separately over 1-Wire — for example, for refrigerated vehicles and cargo monitoring.
In telemetry the fuel level is transmitted as the lls_X_val parameter:
1–4 — RS-485 or BLE;5–8 — RS-485 only.Wired and wireless sensors share the same addresses. Before writing the MAC address of a BLE sensor, make sure the selected slot is not taken by a wired sensor.
The MAC address is written into slots 1–4 through the local configurator ("Settings → Bluetooth sensors") or with SMS commands 5430–5433. After writing, check RSSI: −80 dBm and better — stable, −90 dBm and worse — the connection will drop.
If the readings do not arrive, first check the address and the channel, then the calibration and the report settings in the monitoring system.
Instruction
Time to complete: 40 minutes
RS-485 — for wired sensors and a stable link on special-purpose machinery and long-haul tractors. BLE — when minimal installation is needed without running a cable across the tank.
Mount the fuel level sensor according to the manufacturer instructions: the length and position of the sensor must match the tank. For temperature sensors use the 1-Wire interface.
Wired sensors can use addresses 1–8, wireless ones only 1–4. The address and MAC address must match the unit settings; do not let addresses overlap.
In the configurator, on the "Monitoring" tab, check the fuel level and RSSI for BLE. In telemetry the parameters arrive as lls_X_val.
Fill the tank and compare the readings with the actual volume. If they differ, check the sensor calibration and the settings in the monitoring system.
If it does not work
No readings are coming in
Check the sensor address and the channel: RS-485 — the cable and power, BLE — the MAC address and the battery. For BLE the first detection takes up to 60 seconds.
The fuel level "jumps"
Check the calibration and the sensor position in the tank. For BLE assess RSSI: at −90 dBm and worse the link is unstable.
The temperature sensor is not visible
Check the 1-Wire connection and the device address. Temperature sensors do not use the fuel sensor channels and are configured separately.
Reviewed: 17.11.2026
Read next
Short definitions of the terms found in documentation, contracts and ERA-GLONASS equipment requirements.
UVEOS BOTHERTZ-24 · ASN BOTHERTZ-24
What a dangerous goods carrier needs to configure: ASN, transmission to GAIS, documents and typical mistakes when equipping a fleet.
ASN BOTHERTZ-24
What is checked in UVEOS acoustic tests, how the test is performed in the vehicle and why the 1–5 day timeframe matters for an assembly line.
UVEOS BOTHERTZ-24
Next step
Describe your task and we will prepare a quote with the model, activation cost and delivery timeline. We reply within one business day.